Figure #1
Vent Housing Assembly
(MIS-6778)
5/16" x 1.1/4"
Nuts & Bolts
Figure #2
Hold-Down
Angle
(MIS-4404)
Long Side
Approx.
15.7/8"
Short Side
Approx.
15.3/8"
ASSEMBLY
1. Take all parts out of the shipping box and check
if all parts are present.
2. Turn one (1) roof vent housing (MIS-6778) up-
side down. (See Figure #1)
3. Insert 5/16" x 1.1/4" bin bolt with neoprene
washer through hole in the side of the roof vent.
Place jamb nut onto the bolt and tighten. (See Fig-
ure #1).
4. Slide on eyelet of Grill Guard onto the 5/16" bin
bolt.
5. Insert 5/16" x 1.1/4" bin bolt with neoprene
washer through the other side of the roof vent,
through jamb nut and other eyelet of Grill Guard.
Tighten nut against vent housing side.)
Grill Guard
(MIS-6766)
The following instructions are for assembling and installing the Wire Grill Guard Roof Vent. First,
check the packing list to ensure all components have been shipped. The unit is easiest assembled in
the upside down position as shown in the instructions. Roof vent location should be as shown on
the reverse page.
Wire Grill Guard Roof Vent Assembly & Installation Instructions
WIRE GRILL GUARD ROOF VENT
6. Apply a bead of tube caulking around three(3)
housing sides of the roof vent where it meets the
holddown angle.
7. Place holddown angle (MIS-4404) on the as-
sembled roof vent. The wide end of the hole-down
angle must face vent discharge. Once aligned, screw
nine (9) #10 self drilling (S-280) screws through the
roof housing and into the holddown angle. (See Fig-
ure #2).
PNEG-104
Caulk with tube caulking
(Three sides of vent housing)